Burns
Volume 30, Issue 2 , Pages 109-114, March 2004

Skin elasticity meter or subjective evaluation in scars: a reliability assessment

  • Lieneke J Draaijers

      Affiliations

    • Burn Centre, Red Cross Hospital, Beverwijk, The Netherlands
    • Department of Dermatology, VU Medical Centre, Amsterdam, The Netherlands
    • Corresponding Author InformationCorresponding author. Tel.: +31-251-265555; fax: +31-251-218389.
  • ,
  • Yvonne A.M Botman

      Affiliations

    • Department of Surgery, Red Cross Hospital, Beverwijk, The Netherlands
  • ,
  • Fenike R.H Tempelman

      Affiliations

    • Burn Centre, Red Cross Hospital, Beverwijk, The Netherlands
  • ,
  • Robert W Kreis

      Affiliations

    • Burn Centre, Red Cross Hospital, Beverwijk, The Netherlands
    • Department of Surgery, Red Cross Hospital, Beverwijk, The Netherlands
    • Department of Surgery, VU Medical Centre, Amsterdam, The Netherlands
  • ,
  • Esther Middelkoop

      Affiliations

    • Burn Centre, Red Cross Hospital, Beverwijk, The Netherlands
    • Dutch Burn Foundation, Beverwijk, The Netherlands
  • ,
  • Paul P.M van Zuijlen

      Affiliations

    • Burn Centre, Red Cross Hospital, Beverwijk, The Netherlands
    • Department of Plastic, Reconstructive and Hand Surgery, Academic Medical Centre, Amsterdam, The Netherlands

Abstract 

Various methods are available for evaluating the elasticity of scars. However, the reliability and validity of these methods have been sparsely examined. The aim of this study was to examine the reliability of the subjective evaluation of scar pliability, while at the same time testing the reliability of the measurements of a non-invasive suction device (Cutometer® Skin Elasticity Meter 575) on scars. Four observers assessed 49 scar areas of 20 patients with a subjective assessment of pliability. Subsequently, each observer measured the scar areas with the Cutometer. The intraclass correlation coefficients (ICC) of the elasticity (Ue) and extension (Uf) parameters of the Cutometer were acceptable (r=0.76 and 0.74, respectively) when a single observer carried out the measurements. The subjective assessment of pliability needs to be completed by two or more observers to make the evaluation reliable (r=0.79). The concurrent validities between the subjective pliability–assessment and each of the Cutometer parameters were statistically significant and ranged from r = 0.29–0.53. The correlations between each of the Cutometer parameters were high and statistically significant (r⪖0.71). Conclusion: A single observer can reliably use the Cutometer for the elasticity measurements of scars. Furthermore, either Ue or Uf, instead of all five elasticity values provided by the Cutometer, can be adequately used for the elasticity measurements of scars. The subjective assessment of pliability of scars can only be assessed reliably when completed by two or more observers. The concurrent validity showed that all Cutometer parameters, except for visco-elasticity (Uv), and the subjective assessment of pliability measured the same characteristic of a scar.

Keywords:  Quantification of scar pliability, Reliability, Validity, Correlation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0305-4179(03)00247-X

doi:10.1016/j.burns.2003.09.003

Burns
Volume 30, Issue 2 , Pages 109-114, March 2004